Fluorescent
General Purpose / Industrial Light Fixtures
|

229H Series
Open Fixture
General Purpose Lighting |
Open Industrial fixture.
General Lighting.
UL 1598 approved.
Electronic Ballast.
Even lamp spacing for optimum light distribution.
Pre-wired with wire 5 foot leads for ease of wiring.
Twist lock lampholders.
|
| |
|
Vapor / Dust Proof Fluorescent Lighting Fixtures
|

Model
240
Front Access |
Class
I, Div. 2, Groups A, B, C and D.
Class II, Div. 2, Groups F and G.
Listed for damp locations.
Listed for locations having deposits of readily combustible paint
residues.
Spring loaded lamp holders.
Some applications include: prep areas, inspection areas, sanding
and maching, coal dust, grain dust.
|

Model
241
Rear Access |
UL and ETL listed for U.S. and Canada.
Class I, Div. 2, Groups A, B, C and D.
Class II, Div. 2, Groups F & G.
Listed for damp locations.
For paint spray applications.
Listed for locations having deposits of readily combustible paint
resdues.
Spring loaded lamp holders.
|

Model
260
Inside and Rear Access |
Increased photometric output and efficiency as a result of our wider
fixture design.
Hinged inside access door frame and a piano hinged rear access door
panel which allows for servicing from either inside or outside of
the booth. Inside access features an interlock switch to be wired
in such a way as to disable paint spray equipment when the front
access panel is opened. This unit may be mounted in spray booth
panels without the previously required second lens. Look at 261
for further details.
|

Model
261
Rear Access |
Increased photometric output and efficiency as a result of our wider
fixture design.
Rear access door panel designed for accessing fixture from outside
the booth.
Class I, Div. 2, Groups A, B, C and D.
Class II, Div. 2, Groups F & G.
Listed for locations having deposits of readily combustible paint
reside.
Meets NFPA 33 requirements for inside access.
|

Model
280
Front / Rear Access |
8 Ft. 4 lamp Fluorescent Lighting for Hazardous locations.
ETL listed U.S. and Canada.
Class I, Div. 2 Groups A, B, C and D.
Class II, Div. 2, Groups F and G.
Meets NFPA 33 requirements for inside access.
Two piano hinged inside access door frames and hinged rear access
door panel which allows for servicing from either inside or outside
of the booth.
|

Slim
Light Series
3 and 4 Ft. |
UL and ETL listed in U.S. and Canada.
Class I, Div. 2, Groups A, B, C and D.
Class II, Div. 2, Groups F & G.
Listed for locations having deposits of readily combustible paint
resides.
Inside access features an interlock switch to be wired in such a
way as to disable paint spray equipment when the front access panel
is open.
Meets NFPA 33 requirements for inside access.
|

Model
400
Slim Light Rear Access
4 Ft. 2, 4 & 6 Lamp |
4 Ft. 4 lamp fluorescent lighting for hazardous locations.
Energy efficient.
For paint spray booth applications.
ETL listed for U.S. and Canada.
Class I, Div. 2 Groups A, B, C, D
Class II Div. 2 Groups F, G.
UL listed 441 series.
Listed for locations having deposits of readily combustible
paint resides.
Inside access features an interlock switch to be wired in such a
way as to disable paint spray equipment with the front access panel
is opened.
Meets NFPA 33 requirements for inside access.
|

Model
440T
T-5 Troffer |
2'x4' Enclosed and gasketed T-5 troffer.
Ideal for clean rooms.
Space saving design, only 2 1/4" deep.
End of lamp life sensing.
ETL listed in U.S. and Canada.
Class I, Div. 2, Groups A, B, C and D.
Class II, Div. 2, Groups F & G.
Operates efficiently at higher temperatures than T-8 and T-12 lamps.
Lumen to watt ratio of 90 plus.
100% ballast factor.
|

Model
440 2x4
T-8 Troffer |
2'x4' Enclosed and gasketed T-8 troffer.
Ideal for clean rooms.
Space saving design, only 2 1/4" deep.
End of lamp life sensing.
ETL listed in U.S. and Canada.
Class I, Div. 2, Groups A, B, C and D.
Class II, Div. 2, Groups F & G.
Operates efficiently at higher temperatures than T-8 and T-12 lamps.
Lumen to watt ratio of 90 plus.
100% ballast factor.
|
Wet / Damp / Marine Series Fluorescent Light Fixture
|
|
376 Series Wet/Damp fixture is IP 55 and IP 65 rated and is the intelligent alternative to the traditional style of weatherproof enclosures. Rather than having to add the expense and weight of a strip fixture, the 376 has a gear tray that efficiently carries the electrical components. These UL rated enclosures are designed to be part of the fixture rather than a rain cover. |

384
Series
Marine Location |
Meets all Coast Guard specifications.
CSA certified for hazardous locations.
US 844: Class I, Div. 2, groups A, B, C and D.
UL 595: Outdoor Marine type (saltwater).
For industrial, marine/wet and drill rig
Hazardous locations
|
Inspection Series Fluorescent Light Fixture
|
Four or Eight Foot Two Lamp
Inspection Lighting
|
4 Ft. and 8 Ft. 2 lamp inspection lighting.
Hazardous Locations.
UL Listed 1598 and UL-C listed.
ETL and ETC-C listed for Class I Div. 2 and Class II Div.2.
Model 39042L INS-3613 (4 Ft.) and
39082L INS120-3281(8 Ft.) or 39082L INS277-3532(8 Ft.).
|
387 Series - H.I.D. / C.F.L. Vapor Proof Series
|

387 Series
HID /CFL Vapor Proof
(Ceiling Mount) |
High Pressure Sodium ( 35, 50, 70, 100 watts)
Metal Halide (50, 70, 100 watts)
Compact Fluorescent (13, 26, 32 and 42 watt)
Non-Hazardous Locations
UL 1598
Certified for Wet Locations
High temperature silicone internal gaskets
Weatherproof ballast box
Ceiling (3/4" and 1/2")
Bracket (3/4" and 1/2") |
380 Series - Explosion Proof Series
|

380 Series
Explosion Proof
4 Lamp Fixture
Also available in 2 Lamp |
Hazardous locations
Paint spray booth
Marine/shipboard
Factory sealed
UL listed 595, 844, 1598
Light Weight
Low Profile
|